The following bug has been CLOSED
=======================================================================
http://131.152.105.154/mantis/view_bug_page.php?f_id=0000012
=======================================================================
Reporter: ofels_admin
Handler: sandman
=======================================================================
Project: OPIE
Bug ID: 0000012
Category: Core
Reproducibility: always
Severity: major
Priority: high
Status: closed
=======================================================================
Date Submitted: 06-18-02 12:25 CEST
Last Modified: 06-27-02 10:20 CEST
=======================================================================
Summary: Calibration doesn't detect rotated touch screen
controller.
Description:
X and Y coordinates of the touch screen controller on my development box
are
swapped.
Qt can handle this just fine with an appropriate /etc/pointercal file.
The Opie calibration utility can't though -- its sanityCheck routine
doesn't
allow the calibration to proceed. I needed to hack the kernel to swap X and
Y
coordinates, calibrate, edit /etc/pointercal to swap numbers around in
the
calibration matrix, then revert to a normal kernel.
=======================================================================
-----------------------------------------------------------------------
sandman - 06-18-02 19:22 CEST
-----------------------------------------------------------------------
Since dwmw does not have his rotated TS available for testing, we decided,
that the code looks ok, so it should work.
-----------------------------------------------------------------------
ofels - 06-27-02 10:20 CEST
-----------------------------------------------------------------------
Calibrate works ok again
Received on Thu Jun 27 14:25:37 2002