On Thu, 21 Sep 2000, Nils Faerber wrote:
> - put the CPU into standby mode. But we will have a problem with the date/time
> clock since there is no real time clock to sync against when we leave standby.
Yes there is a RTC in the SA1110.
> Isn't there any timer that could be used to interrupt the standby at a fixed
> time interval to update the clock?
That's exactly what's happening in Linux already when CPU usage is below
100%. The CPU may drain as little as 50mA when you're idle at a prompt.
Nicolas